2010-04
2013-03
2013-03
0
NCT01094626
Columbia University
Columbia University
INTERVENTIONAL
Secretin-enhanced Magnetic Resonance Imaging (S-MRI) for Pancreatic Cancer Detection
The aim of the study is to evaluate the utility of secretin-enhanced MRI (S-MRI) in detecting and measuring pancreatic lesions in patients with known adenocarcinoma or Intraductal papillary mucinous neoplasm (IPMN) lesions. The hypothesis is that S-MRI is superior to MRI without secretin enhancement (N-MRI) in increasing tumor conspicuity, allowing for improved identification and more accurate measurement of lesions or precursor lesions in the pancreas.
Pancreatic cancer remains the fourth leading cause of cancer-related death in the United States and is marked by advanced stage at diagnosis and a high mortality rate. Intraductal papillary mucinous neoplasm (IPMN) is a cystic lesion that can be potentially cancerous, leading to pancreatic adenocarcinoma. Currently, there is no existing imaging modality that is both sensitive and cost-effective enough in accurately measuring or detecting adenocarcinoma and IPMN. Improving the methods used in identification and localization of this disease is critical. Secretin, a hormone produced by duodenal mucosal cells increases blood-flow to the pancreas. The investigators' hypothesis is that as secretin increases blood flow to the pancreas, there will be increased conspicuity in areas of dysplasia/cancer where there is minimal blood-flow, enhancing tumor detection. The investigators are conducting a prospective, randomized-control pilot study of thirty subjects with IPMN or pancreatic cancer who are undergoing surgical resection at Columbia University's Pancreas Center. Fifteen subjects will be randomly selected to undergo S-MRI prior to surgery and fifteen subjects will be selected as controls, undergoing MRI without secretin-enhancement and matched for age, sex, race and tumor-type. The investigators will first evaluate if secretin allows for increased tumor conspicuity, enhanced visualization of the lesion, by comparing the calculated tumor conspicuity of S-MRI to N-MRI groups. The investigators will then assess if S-MRI imaging allows for increased accuracy in lesion measurements by looking at the concordance in measurements between S-MRI and tumor specimens post-resection as compared to the concordance in measurements between N-MRI and tumor specimens post-resection.
These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.
Study Registration Dates | Results Reporting Dates | Study Record Updates |
---|---|---|
2010-03-25 | N/A | 2016-06-08 |
2010-03-26 | N/A | 2016-06-10 |
2010-03-29 | N/A | 2016-06 |
This section provides details of the study plan, including how the study is designed and what the study is measuring.
Primary Purpose:
Diagnostic
Allocation:
Randomized
Interventional Model:
Parallel
Masking:
None
Arms and Interventions
Participant Group/Arm | Intervention/Treatment |
---|---|
EXPERIMENTAL: Experimental Fifteen subjects will be randomly selected to undergo S-MRI prior to surgery. These subjects would receive Secretin, administered by IV bolus injection over 1 minute followed by a 30 second saline flush. | DRUG: Secretin
|
NO_INTERVENTION: Controls Fifteen subjects will be selected as controls, undergoing MRI without secretin-enhancement and matched for age, sex, race and tumor-type. |
Primary Outcome Measures | Measure Description | Time Frame |
---|---|---|
Difference in lesion conspicuity between S-MRI and N-MRI | The primary outcome is whether S-MRI allows for better tumor detection secondary to anticipated increased conspicuity of tumor due to secretin's effect on increasing blood flow to the normal pancreas as compared to N-MRI. Determining S-MRI's efficacy versus that of N-MRI will be carried out by comparing tumor conspicuity measurements in S-MRI and N-MRI groups. Tumor conspicuity will be measured by calculating the contrast to noise ratio, placing region of interest (ROI) on tumor and adjacent tissue and dividing by image noise. | 30 days |
Secondary Outcome Measures | Measure Description | Time Frame |
---|---|---|
Concordance of tumor measurements between S-MRI images and tumor specimens post-resection vs. concordance of tumor measurements between N-MRI and tumor specimens post-resection | The secondary outcome will be the discrepancy in tumor size estimated from MRI and "confirmed" from post-surgical specimens. Tumor size estimated from MRI scans will be determined by measuring the greatest linear dimension (metric) of the lesion. Tumor size estimated by pathology will be directly measured using a linear scale (metric), taking the greatest linear dimension of the resected tumor. The discrepancy in estimated versus "confirmed" tumor size will be compared between S-MRI and N-MRI groups. | 45 days |
This section provides the contact details for those conducting the study, and information on where this study is being conducted.
Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person’s general health condition or prior treatments.
Ages Eligible for Study:
ALL
Sexes Eligible for Study:
18 Years
Accepts Healthy Volunteers:
This is where you will find people and organizations involved with this study.
The person responsible for entering information about the study voluntarily provides these publications. These may be about anything related to the study.
General Publications
No publications available
NPCF was founded on May 29, 2009 and is a 501(c)(3) organization. All donations are tax deductible.
The information and services provided by the National Pancreatic Cancer Foundation are for informational purposes only. The information and services are not intended to be substitutes for professional medical advice, diagnosis or treatment. The National Pancreatic Cancer Foundation does not recommend nor endorse any specific physicians, products or treatments even though they may be mentioned on this site.