2018-11-01
2019-12-13
2020-08-30
192
NCT03622229
Azienda Ospedaliera Universitaria Integrata Verona
Azienda Ospedaliera Universitaria Integrata Verona
INTERVENTIONAL
EUS-FNB for Solid Pancreatic Lesions: Side-fenestrated Vs Fork-tip Needle
Rationale: Until now there are no prospective studies comparing the 22 gauge and 25 gauge side-fenestrated and fork-tip needles. In the present study we will compare the two types of needles in terms of histological yield for the evaluation of solid pancreatic lesions in the absence of rapid on-site evaluation (ROSE). Moreover diagnostic accuracy and the number of passes necessary to achieve the maximum diagnostic and histological yield, and safety will be investigated. Objectives: To evaluate and compare the histologic retrieval rate of two different EUS-FNB needles of the same caliber (22 or 25 gauge). The passes will be 3 for each patient. Study design: Randomized monocentric trial. Study population: Patients ≥18 years old, referred for EUS-guided tissue sampling of a solid pancreatic mass. Intervention: EUS-guided tissue acquisition by mean EUS-FNB, using one of the following FNB needles: side-fenestrated 22 gauge, side-fenestrated 25 gauge, fork-tip 22 gauge or fork-tip 25 gauge. Main study parameters/endpoints: The main endpoint is the histologic yield (defined as the percentage of a tissue core of at least 550 micron at the greatest axis), obtained at each of the 3 needle passes. Secondary endpoints include: i) safety; ii) concordance between macroscopic on-site evaluation (MOSE) and histopathological evaluation ; iii) Accuracy using 1, 2 or 3 passes.
Endoscopic ultrasound (EUS) has become an essential procedure in the last decade for evaluation of focal pancreatic lesions and for tissue acquisition for diagnostic purposes. In these patients the endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) and, more recently, the introduction of EUS fine needle biopsy (EUS-FNB), is a safe instrument, with high sensitivity (75-98 %) and specificity (71-100%). The obtaining of bioptic tissue samples reduces the need for rapid on site-evaluation (ROSE) and allows an easier interpretation of the diagnosis even by non-expert pathologist. It also makes possible to perform ancillary investigations such as immunohistochemical, often useful for the differential diagnosis. Two different EUS-FNB needles are available: the side-fenestrated reverse bevel and the fork-tip forward-acquiring". Both are available in 25, 22 and 19 gauge. The 22 gauge is the most commonly used since it combines the ease of use of small-sized caliber with the advantages of larger sized needles. The 25 gauge is universally recognized as the most manageable and flexible needle and is preferred when the lesion is small (<20mm) or is in ȭifficult" conditions (lesion localized to the uncinate process or to distal tail, lesion distant from the transducer > 15mm, need to cross > 1cm of healthy pancreas, angled position of the instrument). There are no prospective studies comparing the 22 and 25 gauge side-fenestrated and fork-tip needles. We therefore propose a prospective randomized study, to compare the two types of needles in terms of histologic and diagnostic yield, number of passes necessary to reach it in solid pancreatic lesions, in the absence of ROSE. This is a randomized single center trial with two parallel arms in a (1:1) ratio. Consecutive patients with solid pancreatic masses and an indication to perform EUS-guided tissue acquisition will be evaluated and, if eligible, will be enrolled into the study. Randomization will take place after the lesion will have been visualized with EUS and the patient will be found suitable for inclusion. The choice of needle gauge (22 or 25 gauge) will be at the discretion of the endosonographer in relation to the difficulty/risk of the procedure; therefore, two randomization lists will be drawn up, (one for the 22 gauge and one for the 25 gauge). The choice of the needle gauge will be done before randomization so that the choice of the needle does not create bias in the results. The pathologist will be blinded to the needle caliber and type. The sample size has been calculated for the primary outcome (histologic retrieval rate) using a group sequential design to define a proper interim analysis after at least 50% enrolment. The histologic yield of the two needle types can be summarized as follows: 22 gauge: 77% and 92% for the side-fenestrated and the fork-tip, respectively. 25 gauge: 60.5% and 85% for the side-fenestrated and the fork-tip, respectively. With a type I error α of 5% and a power 1 - β of 80%, the total required sample size amounts to 330 patients (210 patients for 22G group and 120 patients for 25G group). Considering that 18% of patients must be added to counteract the estimated and lost drop-out rate at follow-up, overall 362 patients will be needed (196 patients for the 22G group and 112 patients for the 25G group). Based on sample size calculation the two lists will consist in 24 blocks of 8 patients and 1 block of 4 patients for the 22G group and 14 blocks of 8 patients for the 25G group.
These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.
Study Registration Dates | Results Reporting Dates | Study Record Updates |
---|---|---|
2018-07-06 | N/A | 2021-01-13 |
2018-08-07 | N/A | 2021-01-14 |
2018-08-09 | N/A | 2021-01 |
This section provides details of the study plan, including how the study is designed and what the study is measuring.
Primary Purpose:
Diagnostic
Allocation:
Randomized
Interventional Model:
Parallel
Masking:
None
Arms and Interventions
Participant Group/Arm | Intervention/Treatment |
---|---|
ACTIVE_COMPARATOR: EUS-FNB with side-fenestrated needle Before randomization, the endosonographer chooses the needle gauge to perform biopsy preferring the 25 gauge caliber for "difficult" lesions. The needle advances inside the lesion and the operator will perform some needle movements back and forth into the | DIAGNOSTIC_TEST: Histologic evaluation
|
ACTIVE_COMPARATOR: EUS-FNB with fork-tip needle Intervention: like above. Diagnostic Test: Histologic evaluation. | DIAGNOSTIC_TEST: Histologic evaluation
|
Primary Outcome Measures | Measure Description | Time Frame |
---|---|---|
EUS-FNB procurement yield of tissue "core" using two different FNB needles. | Procurement percentage of a "core" (defined as a piece of tissue at least 550 micron in the greatest axis) in the two arms. | 6 months |
Secondary Outcome Measures | Measure Description | Time Frame |
---|---|---|
Diagnostic accuracy. | Diagnostic accuracy (defined as the ratio between the sum of true positive and true negative values divided by the number of lesions) will be calculated for each study arm. | 6 months |
Diagnostic accuracy according to the number of needle passes | Diagnostic accuracy (defined as the ratio between the sum of true positive and true negative values divided by the number of lesions) will be calculated after 1, 2 or 3 needle passes in the two study arms. | 6 months |
Histologic retrieval rate according to the number of needle passes | Percentage of tissue core (defined as an intact piece of tissue of at least 550 micron in the greatest axis) will be calculated after 1, 2 or 3 needle passes in the two study arms. | 6 months |
Procedure related adverse events | Percentage of intra-procedural and post-procedural adverse events in the 2 arms (e.g haemorrhage, perforation, pancreatitis) will be compared. | 6 months |
Procedure related serious adverse events. | Percentage of serous adverse events in the 2 arms (e.g long hospitalization, disability, death) will be compared. | 6 months |
Samples tissue integrity | Tissue integrity will be evaluated by attributing a score from zero to 6 (6 represents the better outcome), according to the following score system: 0=Insufficient material for interpretation. 1=Sufficient material for limited cytological interpretation; probably not representative. 2=Sufficient material for adequate cytological interpretation. 3=Sufficient material for low quality histological interpretation (tissue fragments < 550 micron in greatest axis). 4=Sufficient material for good quality histological interpretation (1 to 5 cores > 550 micron in greatest axis). 5=Sufficient material for high quality histological interpretation (6 to 10 cores > 550 micron in greatest axis). 6=Sufficient material for excellent quality histological interpretation (more than 10 cores > 550 micron in greatest axis or total tissue length > 5.500 micron); | 6 months |
Samples blood contamination | Blood contamination will be evaluated by attributing a score from 0 to 3 (3 represents the better outcome), according to the following score system: 0=Only blood; 1=Much blood contamination, surface area > 50 % of the slide; 2=Medium blood contamination, surface area 25-50 % of the slide; 3=Little blood contamination, surface area < 25 % of slide. | 6 months |
Macroscopic on-site evaluation (MOSE) | Concordance between presence of a core at Macroscopic on-site evaluation (MOSE) and presence of core at histopathological evaluation. | 6 months |
This section provides the contact details for those conducting the study, and information on where this study is being conducted.
Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person’s general health condition or prior treatments.
Ages Eligible for Study:
ALL
Sexes Eligible for Study:
18 Years
Accepts Healthy Volunteers:
This is where you will find people and organizations involved with this study.
The person responsible for entering information about the study voluntarily provides these publications. These may be about anything related to the study.
General Publications
NPCF was founded on May 29, 2009 and is a 501(c)(3) organization. All donations are tax deductible.
The information and services provided by the National Pancreatic Cancer Foundation are for informational purposes only. The information and services are not intended to be substitutes for professional medical advice, diagnosis or treatment. The National Pancreatic Cancer Foundation does not recommend nor endorse any specific physicians, products or treatments even though they may be mentioned on this site.