Clinical Trial Record

Return to Clinical Trials

Fine Needle Biopsy of Solid Pancreatic Mass Lesions


2019-09-09


2020-06-25


2020-12


130

Study Overview

Fine Needle Biopsy of Solid Pancreatic Mass Lesions

This is a randomized trial to evaluate and directly compare the tissue quality, diagnostic sucess and safety profile of four different Fine Needle Biopsy needles.

Endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) is currently the standard method for sampling solid pancreatic masses, with reported sensitivity for malignant cytology of 85-95%, specificity of 95-98% and diagnostic accuracy of 78-95%. Diagnostic failure of EUS-FNA can be due to inadequate targeting, inexperience of the endoscopist/pathologist, or necrotic or fibrotic tumors in which viable cells are difficult to obtain. The cellularity and architectural representation of the sample can also be determined by the needle used and its specific features. Recently, new needles known as ȯine needle biopsy (FNB)" needles have become available that are specially designed to promote the collection of core tissue by unique designs of their needle tips. The advantages of FNB over FNA needles are that (a) the quality of tissue procured is superior: FNA needles yield cytology whereas FNB needles yield histology (b) molecular marker analysis can be performed more reliably on histology samples than cytology aspirates and (c) as histological tissue is greater in quantity than cytological aspirates, a quicker diagnosis with fewer passes can be established by histology than cytology. Four different types of FNB needles are currently available - reverse-bevel tip (EchoTip ProCore HD Ultrasound Biopsy Needle, Cook Medical, Bloomington, IN), Menghini-tip (EZ shot, Olympus America, Center Valley, PA), Franseen tip (Acquire, Boston Scientific Corporation, Natick, MA) and fork-tip (SharkCore, Medtronic Corporation/Covidien, Newton, MA) needles, each with unique tip designs to facilitate procurement of histological core tissue. Although we have previously compared in randomized trials the diagnostic yield of Franseen and fork-tip FNB needles and have shown the two needles to be equivalent, there are currently no randomized trials directly comparing all four FNB needle types. EUS-guided tissue acquisition can also be performed using different techniques, including the use of suction, no use of suction and the stylet retraction technique. There are currently no studies comparing these different tissue acquisition techniques using the different FNB needles and no study has demonstrated the best technique for FNB.

  • Pancreatic Neoplasms
  • DIAGNOSTIC_TEST: Solid pancreatic mass lesion biopsy
  • 1469116

Study Record Dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Registration Dates Results Reporting Dates Study Record Updates

2019-09-09  

N/A  

2020-08-03  

2019-09-09  

N/A  

2020-08-05  

2019-09-11  

N/A  

2020-08  

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

Design Details

Primary Purpose:
Diagnostic


Allocation:
Randomized


Interventional Model:
Single Group


Masking:
Triple


Arms and Interventions

Participant Group/ArmIntervention/Treatment
ACTIVE_COMPARATOR: 22 Gauge FNB Needle - ProCore

The 22 Gauge FNB Needle - ProCore will be used to biopsy solid pancreatic mass lesions.

DIAGNOSTIC_TEST: Solid pancreatic mass lesion biopsy

  • The needle will be used to puncture the lesion and remove a piece of tissue from the mass for histological diagnosis.
ACTIVE_COMPARATOR: 22 Gauge FNB Needle - Acquire

The 22 Gauge FNB Needle - Acquire will be used to biopsy solid pancreatic mass lesions.

DIAGNOSTIC_TEST: Solid pancreatic mass lesion biopsy

  • The needle will be used to puncture the lesion and remove a piece of tissue from the mass for histological diagnosis.
ACTIVE_COMPARATOR: 22 Gauge FNB Needle - SharkCore

The 22 Gauge FNB Needle - SharkCore will be used to biopsy solid pancreatic mass lesions.

DIAGNOSTIC_TEST: Solid pancreatic mass lesion biopsy

  • The needle will be used to puncture the lesion and remove a piece of tissue from the mass for histological diagnosis.
ACTIVE_COMPARATOR: 22 Gauge FNB needle - EZ Shot 3 Plus

The 22 Gauge FNB Needle - EZ Shot 3 Plus will be used to biopsy solid pancreatic mass lesions.

DIAGNOSTIC_TEST: Solid pancreatic mass lesion biopsy

  • The needle will be used to puncture the lesion and remove a piece of tissue from the mass for histological diagnosis.
Primary Outcome MeasuresMeasure DescriptionTime Frame
Degree of cellularity in biopsy sampleCompare the degree of cellularity of the obtained tissue in the biopsy sample between the four FNB needles in patients undergoing EUS-guided sampling of pancreatic masses using the three different sampling techniques. Cellularity is defined as the proportion of core tissue to total specimen area.3 days
Secondary Outcome MeasuresMeasure DescriptionTime Frame
Diagnostic adequacy of the biopsy sampleDocumentation of the presence of adequate tissue material (pancreatic parenchyma and tumor if applicable) in the biopsy sample.1 day
Specimen bloodiness in biopsy sampleMeasured as the area of bloodiness in the biopsy sample, with calculation as a percentage in the microscopic field.1 day
Presence of crush artefact in biopsy sampleDocumenting the presence or absence of crush artefact in the biopsy sample. If present, it is measured as the area of artefact in biopsy sample, with calculation as a percentage in relation to the total sample area.1 day
Technical failureMeasured as the inability to successfully perform the fine needle biopsy using the assigned needle, due to any needle dysfunction.1 day
Adverse eventsThe subject will be asked to report and medical records will be reviewed for any adverse events related to the procedure or the underlying disease.7 days, 30 days, and 6 months
Diagnostic operating characteristicsCompare the diagnostic operating characteristics of the biopsy sample and detection of neoplasia (defined as sensitivity, specificity, negative predictive value, positive predictive value and accuracy) between the four FNB needles in patients undergoing EUS-guided sampling of pancreatic masses using the three different sampling techniques6 months

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Contact

Name: Shyam Varadarajulu, MD

Phone Number: 407.303.2750

Email: shyam.varadarajulu.md@adventhealth.com

Study Contact Backup

Name: Robin Barron-Nelson

Phone Number: 321.946.2747

Email: robin.barron@flhosp.org

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person’s general health condition or prior treatments.

Ages Eligible for Study:
ALL

Sexes Eligible for Study:
18 Years

Accepts Healthy Volunteers:

    Inclusion Criteria:
    1. All patients referred for EUS-guided tissue acquisition of suspected or confirmed solid pancreatic mass lesions visualized on any radiological imaging 2. Able and willing to provide written or verbal consent 3. ≥ 18 years old 4. Able to undergo conscious sedation for EUS procedure
    Exclusion Criteria:
    1. <18 years old 2. Unable to obtain informed consent from the patient 3. Medically unfit for sedation 4. Pregnant patients 5. No pancreatic mass lesions visualized on EUS 6. Irreversible coagulopathy as determined by platelet count < 50,000/microL or International Normalized Ratio (INR) > 1.5 7. Unable to stop anti-platelet agents prior to the procedure

Collaborators and Investigators

This is where you will find people and organizations involved with this study.


    • PRINCIPAL_INVESTIGATOR: Shyam Varadarajulu, MD, AdventHealth

    Publications

    The person responsible for entering information about the study voluntarily provides these publications. These may be about anything related to the study.

    General Publications

    • Ngamruengphong S, Li F, Zhou Y, Chak A, Cooper GS, Das A. EUS and survival in patients with pancreatic cancer: a population-based study. Gastrointest Endosc. 2010 Jul;72(1):78-83, 83.e1-2. doi: 10.1016/j.gie.2010.01.072.
    • Othman MO, Wallace MB. The role of endoscopic ultrasonography in the diagnosis and management of pancreatic cancer. Gastroenterol Clin North Am. 2012 Mar;41(1):179-88. doi: 10.1016/j.gtc.2011.12.014. Epub 2012 Jan 16.
    • Hewitt MJ, McPhail MJ, Possamai L, Dhar A, Vlavianos P, Monahan KJ. EUS-guided FNA for diagnosis of solid pancreatic neoplasms: a meta-analysis. Gastrointest Endosc. 2012 Feb;75(2):319-31. doi: 10.1016/j.gie.2011.08.049.
    • Varadarajulu S, Fraig M, Schmulewitz N, Roberts S, Wildi S, Hawes RH, Hoffman BJ, Wallace MB. Comparison of EUS-guided 19-gauge Trucut needle biopsy with EUS-guided fine-needle aspiration. Endoscopy. 2004 May;36(5):397-401. doi: 10.1055/s-2004-814316.
    • Bang JY, Hawes R, Varadarajulu S. A meta-analysis comparing ProCore and standard fine-needle aspiration needles for endoscopic ultrasound-guided tissue acquisition. Endoscopy. 2016 Apr;48(4):339-49. doi: 10.1055/s-0034-1393354. Epub 2015 Nov 12.
    • Bang JY, Hebert-Magee S, Navaneethan U, Hasan MK, Hawes R, Varadarajulu S. EUS-guided fine needle biopsy of pancreatic masses can yield true histology. Gut. 2018 Dec;67(12):2081-2084. doi: 10.1136/gutjnl-2017-315154. Epub 2017 Oct 7. No abstract available.
    • Bang JY, Hebert-Magee S, Navaneethan U, Hasan MK, Hawes R, Varadarajulu S. Randomized trial comparing the Franseen and Fork-tip needles for EUS-guided fine-needle biopsy sampling of solid pancreatic mass lesions. Gastrointest Endosc. 2018 Jun;87(6):1432-1438. doi: 10.1016/j.gie.2017.11.036. Epub 2018 Jan 3.
    • Lee KY, Cho HD, Hwangbo Y, Yang JK, Han SJ, Choi HJ, Lee YN, Cha SW, Moon JH, Cho YD, Park SH, Lee TH. Efficacy of 3 fine-needle biopsy techniques for suspected pancreatic malignancies in the absence of an on-site cytopathologist. Gastrointest Endosc. 2019 Apr;89(4):825-831.e1. doi: 10.1016/j.gie.2018.10.042. Epub 2018 Nov 4.
    • Saxena P, El Zein M, Stevens T, Abdelgelil A, Besharati S, Messallam A, Kumbhari V, Azola A, Brainard J, Shin EJ, Lennon AM, Canto MI, Singh VK, Khashab MA. Stylet slow-pull versus standard suction for endoscopic ultrasound-guided fine-needle aspiration of solid pancreatic lesions: a multicenter randomized trial. Endoscopy. 2018 May;50(5):497-504. doi: 10.1055/s-0043-122381. Epub 2017 Dec 22.
    • Nakai Y, Isayama H, Chang KJ, Yamamoto N, Hamada T, Uchino R, Mizuno S, Miyabayashi K, Yamamoto K, Kawakubo K, Kogure H, Sasaki T, Hirano K, Tanaka M, Tada M, Fukayama M, Koike K. Slow pull versus suction in endoscopic ultrasound-guided fine-needle aspiration of pancreatic solid masses. Dig Dis Sci. 2014 Jul;59(7):1578-85. doi: 10.1007/s10620-013-3019-9. Epub 2014 Jan 16.
    • Chow, S.C.; Shao, J.; Wang, H. 2008. Sample Size Calculations in Clinical Research, 2nd Edition. Chapman & Hall/CRC. Boca Raton, FL. Pages 99-100.
    • Young Bang J, Krall K, Jhala N, Singh C, Tejani M, Arnoletti JP, Navaneethan U, Hawes R, Varadarajulu S. Comparing Needles and Methods of Endoscopic Ultrasound-Guided Fine-Needle Biopsy to Optimize Specimen Quality and Diagnostic Accuracy for Patients With Pancreatic Masses in a Randomized Trial. Clin Gastroenterol Hepatol. 2021 Apr;19(4):825-835.e7. doi: 10.1016/j.cgh.2020.06.042. Epub 2020 Jul 8.